PROFIBUS-DP timeout
Operating Characteristics on PROFIBUS-DP
The following figure shows the corresponding configuration for the MOVI-PLC
®
advanced DHF41B control card in the hardware configuration of STEP7 (→ section "DP
configurations", page 46).
5.2 PROFIBUS-DP timeout
The response monitoring time on the MOVI-PLC
®
advanced DHF41B control card
elapses (if configured in the DP master) if data transmission via the PROFIBUS-DP
system is interrupted or disrupted. The Fault Profibus LED lights up to indicate that no
new user data is being received.
The ProfibusGetInfo function module in the MPLCInterface_Profibus library, which is
run cyclically, displays this PROFIBUS timeout. The fault response can be programmed
explicitly. The application flow can be influenced accordingly.